Innovative sensor design minimizes measurement variations caused by device angle or contact pressure Consistent data quality at both low and high frequency ranges Four-level severity scale assesses urgency of problems for overall vibration and bearing condition Exportable data via USB Trending in Microsoft Excel using built-in templates Overall vibration measurement (10 Hz to 1,000 Hz) for acceleration, velocity and displacement units of measurement for a wide variety of machines Crest Factor+ technology provides reliable bearing assessment using direct sensor tip measurements between 4,000 Hz and 20,000 Hz Colored lighting system (green, red) and on-screen comments indicate how much pressure needs to be applied to take measurements Temperature measurement with Spot IR Sensor increases diagnostic capabilities On-board memory holds and saves up to 3,500 measurements Audio output for listening to bearing tones directly External accelerometer support for hard to reach locations Flashlight for viewing measurement locations in dark areas Large screen with high resolution for easy navigation and viewing
Analyzes common equipment, like motors, fans and pumps, and determines the root cause and location of mechanical failure. Types of Common Equipment which can be Analyzed: Motors Fans and blowers Belts and chain drives Gearboxes Pumps Compressors Spindles Detect the root cause of mechanical failure: Bearing problems Misalignment Unbalance Looseness Intuitive user interface is multilingual and icon-based Tri-axial TEDS accelerometer reduces measurement time Laser Tachometer included for accurate machine running speed and diagnostic confidence Fault severity scale helps you set repair priorities Repair recommendations advise technicians on corrective action On-board diagnostic engine identifies four common faults: misalignment, unbalance, looseness and bearing condition On-board context-sensitive help for real-time tips and guidance Viewer PC Software expands data storage and tracking capacity and imports Fluke thermal images Gives you an immediate fault severity assessment and repair recommendations Helps technicians: Quickly understand machinery health Work more efficiently and effectively Helps managers: Control downtime by...
Fluke VT02 Visual Infrared (IR) Thermometer 10°C to +250°C (14°F to 482°F) Temp. Range, 2°C Accuracy
-10°C to +250°C (14°F to 482°F) Temperature Measurement Range 2°C or 2% (at 25 °C nominal, whichever is greater) Accuracy Detect issues instantaneously with digital and thermal blended images Pinpoint hot and cold spots with temperature markers Perform inspections up to 30 times faster than traditional infrared thermometers Document and communicate problems efficiently with SmartView reporting software
Detect issues instantly with built-in digital camera No training required; Fully automatic with built-in intelligence True pocket size design Breakthrough affordability: Half the cost of infrared cameras that require training and software Exclusive thermal heat map blending overlay Blend digital and thermal images to instantly show the exact location of the issue Blend between 0 %, 25 %, 50 %, 75 %, and full thermal with one button Powerful resolution with PyroBlend Plus optics Best-in-class field of view for tight spaces: 28° x 28° Four times sharper images: VT04 compared to VT02 Alarm and time lapse features Hi/Lo temperature alarm—Screen flashes if user-selected temperature is exceeded Time lapse image capture—automatically capture images Auto-monitor alarm — Automatically capture images after a user-selected temperature alarm has been triggered True pocket size design; Forty percent smaller than entry-level infrared cameras SmartView reporting software Store up to 10,000 images per Gb on included SD card and make professional reports on included professional software
Choice of 1, 2 and 4 independent or linked channels 40 MS/s max. sampling speed 16 MHz function generator 10 MHz pulse generator Pulse train pattern generator Arbitrary waveforms of up to 65 k points Powerful modulation capabilities Built-in trigger generators Waveform Manager Plus for Windows® software Multiple standard waveforms recalled from internal memory RS-232 and GPIB interfaces
1 (Fluke 291), 2 (Fluke 292) or 4 (Fluke 294) independent arbitrary channels Additional DC to 50MHz fixed amplitude sine and squarewave outputs on 2- and 4-channel instruments 100 MS/s 12-bit arbitrary waveform capability 1 M point waveform memory 40MHz function generator capabilities using DDS (50 MHz for square waves) Output level 2.5 mV to 10 V p-p into 50 Ω with 12 bit vertical resolution 10 ns pulse pattern generator Waveform sequencing with up to 1024 segments Unlimited waveform storage using CF® memory card Waveform Manager Plus for Windows software Compact Flash card for non-volatile waveform memory Waveform linking, looping and sequencing Inter-channel triggering, summing, modulation and phase control USB interface in addition to RS-232 and GPIB
LCD w/backlight 3½ digits Crest factor (50 Hz/60 Hz) 3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2 Log rate/interval 1 sec minimum/adjustable by PC or front panel EMC EN 61326-1:2006
True-RMS AC voltage measurements to 1000V LCD w/backlight 3½ digits, 6000 counts, updates 4/sec ±1% accuracy to 500 Hz, ± 2% accuracy to 1 kHz EMC EN 61326-1:2006